955 research outputs found

    Peripheral arterial disease in women

    Get PDF
    Peripheral arterial disease (PAD) affects a significant portion of the United States population, and much research has been conducted on identifying populations at risk for PAD, evaluating appropriate diagnostic modalities for PAD, studying the effect of risk factor reduction on PAD progression, and determining the best method of treatment for symptomatic PAD. However, most PAD research and clinical trials have focused on whole populations, or populations consisting mostly of men. Little data exist with respect to PAD in women. The goal of this review is to highlight what is known about gender-related differences for PAD

    Predicting iliac limb occlusions after bifurcated aortic stent grafting: Anatomic and device-related causes

    Get PDF
    AbstractObjective: Graft limb occlusion may complicate endovascular abdominal aortic aneurysm repair. The precise etiologic factors that contribute to the development of these graft limb thromboses have not been defined. We evaluated our experience with bifurcated aortic endografts to determine factors that may predict subsequent limb thrombosis. The management of the thrombosed limbs and the results after treatment were also investigated. Methods: During a 4-year period, 351 patients with aortic aneurysms underwent treatment with bifurcated endografts (702 graft limbs at risk). These 351 bifurcated devices included AneuRx (Medtronic, Minneapolis, Minn; n = 35), Ancure (Guidant, Menlo Park, Calif; n = 8), Gore (W.L. Gore & Associates, Sunnyvale, Calif; n = 25), Talent (World Medical, Sunrise, Fla; n = 255), Teramed (Teramed, Minneapolis, Minn; n = 10), and Vanguard (Boston Scientific Vascular, Natick, Mass; n = 18). Details regarding the type of device, mechanism of deployment, and aortoiliac artery anatomy were collected prospectively and analyzed. Graft limbs were analyzed for diameter, use of additional endograft iliac extensions, deployment in the external iliac artery, and endograft to vessel oversizing. Follow-up included physical examination, duplex ultrasonography, and spiral computed tomographic scans at 1 month, 6 months, and 12 months and annually thereafter. The follow-up period ranged from 2 to 54 months, with a mean follow-up period of 20 months. Results: Twenty-six of 702 limbs (3.7%) had an occlusion develop. The risk of limb thrombosis was associated with a smaller limb diameter. Mean graft limb diameter was 14 mm in the occluded population, and patent limbs had a mean diameter of 16 mm. Thrombosis occurred in 16 of 291 limbs (5.5%) that were 14 mm or less and in 10 of 411 limbs (2.4%) that were greater than 14 mm (P = .03). Extension of a graft to the external iliac artery was performed in 96 of the 702 limbs. Eight of these 96 limbs (8.3%) had thrombosis develop as compared with 18 of 606 (3.0%) that extended to the common iliac artery (P = .01). No significant association was present between limb thrombosis and the contralateral or ipsilateral side of a device, the configuration of the iliac graft limb end (closed web, open web, or bare spring), or the degree of iliac graft limb oversizing. AneuRx, Ancure, Vanguard, and Talent grafts each sustained limb occlusions, with no occlusions seen among the Gore and Teramed devices. No significant increased risk of graft limb thrombosis was observed in unsupported grafts (1/16; 6.3%) versus supported grafts (25/686; 3.6%; P = not significant). Thromboses occurred between 1 day and 23 months after surgery. Thirteen of the 26 thromboses (50%) occurred within 30 days of surgery. Presenting symptoms were mild to moderate claudication in eight patients (30.8%), severe claudication in 16 patient (61.5%), and paresthesia and rest pain in two patients (7.7%). Eighteen of 26 patients (69.2%) eventually needed intervention to reestablish flow to the occluded limb, including thrombolysis and stenting in two patients (7.7%), axillary femoral bypass in one patient (3.8%), femoral-femoral bypass in 13 patients (50.0%), and axillary-bifemoral bypass in two patients (7.7%). All patients with mild to moderate symptoms under observation had improvement in symptoms with no further interventions necessary. All revascularizations were successful in relieving symptoms. Conclusion: Graft limb occlusion is a recognized complication of endovascular treatment of abdominal aortic aneurysms that may be associated with smaller graft limb diameter and extension to the external iliac artery. Occlusions usually necessitate additional intervention for resolution of ischemic symptoms. The use of small diameter grafts should be avoided when possible to reduce the risk of graft limb occlusions. (J Vasc Surg 2002;36:679-84.

    Management of aneurysms involving branches of the celiac and superior mesenteric arteries: A comparison of surgical and endovascular therapy

    Get PDF
    ObjectiveAneurysms involving branches of the superior mesenteric and celiac arteries are uncommon and require proper management to prevent rupture and death. This study compares surgical and endovascular treatment of these aneurysms and analyzes outcome.MethodsPatients at the Mount Sinai Medical Center in New York who were treated for aneurysms in the branches of the celiac artery and superior mesenteric artery were identified through a search of the institution’s medical records and endovascular database. Patient demographics, history, clinical presentation, aneurysm characteristics, treatments, and follow-up outcome were retrospectively recorded. Significant differences between patients treated by surgical or endovascular therapy were determined by using Student’s t test and χ 2 analysis.ResultsBetween January 1, 1991, and July 1, 2005, 59 patients with 61 aneurysms were treated at a single institution. Twenty-four patients had surgical repair, and 35 underwent endovascular treatment, which included coil embolization and stent-graft therapy. Splenic (28) and hepatic (22) artery aneurysms predominated. Eighty-nine percent of splenic artery aneurysms were true aneurysms and were treated by endovascular and surgical procedures in near equal numbers (14 and 11, respectively). Pseudoaneurysms were significantly more likely to be treated by endovascular means (P < .01). The technical success rate of endovascular treatment for aneurysms was 89%, and failures were successfully treated by repeat coil embolization in all patients who presented for retreatment. Patients treated by endovascular techniques had a significantly higher incidence of malignancy than patients treated with open surgical techniques (P = .03). Furthermore, patients treated by endovascular means had a shorter in-hospital length of stay (2.4 vs 6.6 days, P < .001).ConclusionEndovascular management of visceral aneurysms is an effective means of treating aneurysms involving branches of the celiac and superior mesenteric arteries and is particularly useful in patients with comorbidities, including cancer. It is associated with a decreased length of stay in the elective setting, and failure of primary treatment can often be successfully managed percutaneously

    First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms

    Get PDF
    ObjectivesEndovascular stent graft repair of abdominal aortic aneurysms (AAAs) prevents rupture by excluding the aneurysm sac from systemic arterial pressure. Current surveillance protocols after endovascular aneurysm repair (EVAR) follow secondary markers of sac pressurization, namely, endoleak and sac enlargement. We report the first clinical experience with the use of a permanently implantable, ultrasound-activated remote pressure transducer to measure intrasac pressure after EVAR.MethodsOver 7 months, 14 patients underwent EVAR of an infrarenal abdominal aortic aneurysm with implantation of an ultrasound-activated remote pressure transducer fixed to the outside of the stent graft and exposed to the excluded aortic sac. Twelve patients received modular bifurcated stent grafts, and 2 patients received aortouniiliac devices. Intrasac pressures were measured directly with an intravascular catheter and by the remote sensor at stent-graft deployment. Follow-up sac pressures were measured with a remote sensor and correlated with systemic arterial pressure at every follow-up visit. Mean follow-up was 2.6 ±1.9 months.ResultsExcellent concordance was found between catheter-derived and transducer-derived intrasac pressssure intraoperatively. Pulsatile waveforms were seen in all functioning transducers at each evaluation interval. One implant ceased to function at 2 months of follow-up. In 1 patient a type I endoleak was diagnosed on 1-month computed tomography (CT) scans; 3 type II endoleaks were observed. Those patients with complete exclusion of the aneurysm on CT scans had a significant difference in systemic and sac systolic pressures initially (P < .001) and at 1 month (P < .001). Initial sac diastolic pressures were higher than systemic diastolic pressures (P < .001). The ratio of systemic to sac systolic pressure increased over time in those patients with complete aneurysm exclusion (P < .001). Four of 6 patients with no endoleak and greater than 1-month follow-up had diminution of sac systolic pressure to 40 mm Hg or less by 3 months.ConclusionThis is the first report of a totally implantable chronic pressure transducer to monitor the results of EVAR in human beings. Aneurysm exclusion leads to gradual diminution of sac pressure over several months. Additional clinical follow-up will be necessary to determine whether aneurysm sac pressure monitoring can replace CT in the long-term surveillance of patients after EVAR

    A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms

    Get PDF
    AbstractObjective: The Talent endovascular graft has been used in the treatment of abdominal aortic aneurysms (AAAs) in more than 13,000 patients worldwide. However, information regarding the results of its use has been limited. This report describes the experience with 368 patients with AAAs who underwent treatment at four medical centers as part of an investigator-sponsored investigational device exemption trial. Methods: Patients with AAAs were enrolled at four sites during a 32-month period from January 1999 to July 2001. All patients underwent treatment for infrarenal AAA with the Talent endovascular graft. Repair was performed with transrenal stent fixation under epidural (362/368 patients; 98.3%), local (4/368 patients; 1.1%), or general (2/368 patients; 0.5%) anesthesia. The average diameters were: maximum aortic aneurysm, 6.2 ± 1.2 cm; proximal aortic fixation site, 2.6 ± 0.4 cm; and distal iliac fixation site, 1.4 ± 0.6 cm. Bifurcated grafts were used in 276 of 366 patients (75%), aortouniiliac in 57 of 366 patients (16%), and tube aortoaortic in 33 of 366 patients (9%). Multiple comorbid medical conditions were present in all patients (average, 4.7 conditions/patient). The mean age was 75.8 years, and 85% of the patients were male. Follow-up period ranged from 2 to 33 months (mean, 7.3 months). Results: Endovascular graft deployment was accomplished in 366 of 368 patients. In the 263 patients followed for at least 6 months after endovascular repair, AAA diameter decreased by 5 mm or more in 83 patients (32%); diameter remained unchanged (change < 5 mm) in 157 patients (60%) and increased by 5 mm or more in 23 patients (8.7%). Major morbidity occurred in 46 of 368 patients (12.5%), and minor morbidity occurred in 31 of 368 (8.4%). The 30-day mortality rate was 1.9%. Secondary procedures were performed in 32 patients (8.7%). Late rupture occurred in two patients, and late deaths unrelated to AAA occurred in 32 patients (8.7%) during the follow-up period. The primary technical success rate for all patients was 93.4%. The 30-day primary procedural success rate was 73.3%. The 30-day secondary procedural success rate was significantly higher at 85.8%. Computed tomographic scan was performed within 1 month after surgery in 349 patients. An endoleak was present in 43 of 349 patients (12.3%). These endoleaks were comprised of 10 attachment site (type I; 2.9%), 31 retrograde side-branch (type II; 8.9%), and two transgraft (type III; 0.6%). Conclusion: These midterm findings show a high degree of technical and procedural success achieved in a patient population with extensive comorbid medical illnesses with low perioperative morbidity and mortality rates. Further follow-up study will be necessary to determine the effectiveness of the Talent endograft for the long-term treatment of AAA. (J Vasc Surg 2002;35:1123-8.

    Juxtaposing BTE and ATE – on the role of the European insurance industry in funding civil litigation

    Get PDF
    One of the ways in which legal services are financed, and indeed shaped, is through private insurance arrangement. Two contrasting types of legal expenses insurance contracts (LEI) seem to dominate in Europe: before the event (BTE) and after the event (ATE) legal expenses insurance. Notwithstanding institutional differences between different legal systems, BTE and ATE insurance arrangements may be instrumental if government policy is geared towards strengthening a market-oriented system of financing access to justice for individuals and business. At the same time, emphasizing the role of a private industry as a keeper of the gates to justice raises issues of accountability and transparency, not readily reconcilable with demands of competition. Moreover, multiple actors (clients, lawyers, courts, insurers) are involved, causing behavioural dynamics which are not easily predicted or influenced. Against this background, this paper looks into BTE and ATE arrangements by analysing the particularities of BTE and ATE arrangements currently available in some European jurisdictions and by painting a picture of their respective markets and legal contexts. This allows for some reflection on the performance of BTE and ATE providers as both financiers and keepers. Two issues emerge from the analysis that are worthy of some further reflection. Firstly, there is the problematic long-term sustainability of some ATE products. Secondly, the challenges faced by policymakers that would like to nudge consumers into voluntarily taking out BTE LEI

    Penilaian Kinerja Keuangan Koperasi di Kabupaten Pelalawan

    Full text link
    This paper describe development and financial performance of cooperative in District Pelalawan among 2007 - 2008. Studies on primary and secondary cooperative in 12 sub-districts. Method in this stady use performance measuring of productivity, efficiency, growth, liquidity, and solvability of cooperative. Productivity of cooperative in Pelalawan was highly but efficiency still low. Profit and income were highly, even liquidity of cooperative very high, and solvability was good

    Differential cross section measurements for the production of a W boson in association with jets in proton–proton collisions at √s = 7 TeV

    Get PDF
    Measurements are reported of differential cross sections for the production of a W boson, which decays into a muon and a neutrino, in association with jets, as a function of several variables, including the transverse momenta (pT) and pseudorapidities of the four leading jets, the scalar sum of jet transverse momenta (HT), and the difference in azimuthal angle between the directions of each jet and the muon. The data sample of pp collisions at a centre-of-mass energy of 7 TeV was collected with the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 fb[superscript −1]. The measured cross sections are compared to predictions from Monte Carlo generators, MadGraph + pythia and sherpa, and to next-to-leading-order calculations from BlackHat + sherpa. The differential cross sections are found to be in agreement with the predictions, apart from the pT distributions of the leading jets at high pT values, the distributions of the HT at high-HT and low jet multiplicity, and the distribution of the difference in azimuthal angle between the leading jet and the muon at low values.United States. Dept. of EnergyNational Science Foundation (U.S.)Alfred P. Sloan Foundatio

    Impacts of the Tropical Pacific/Indian Oceans on the Seasonal Cycle of the West African Monsoon

    Get PDF
    The current consensus is that drought has developed in the Sahel during the second half of the twentieth century as a result of remote effects of oceanic anomalies amplified by local land–atmosphere interactions. This paper focuses on the impacts of oceanic anomalies upon West African climate and specifically aims to identify those from SST anomalies in the Pacific/Indian Oceans during spring and summer seasons, when they were significant. Idealized sensitivity experiments are performed with four atmospheric general circulation models (AGCMs). The prescribed SST patterns used in the AGCMs are based on the leading mode of covariability between SST anomalies over the Pacific/Indian Oceans and summer rainfall over West Africa. The results show that such oceanic anomalies in the Pacific/Indian Ocean lead to a northward shift of an anomalous dry belt from the Gulf of Guinea to the Sahel as the season advances. In the Sahel, the magnitude of rainfall anomalies is comparable to that obtained by other authors using SST anomalies confined to the proximity of the Atlantic Ocean. The mechanism connecting the Pacific/Indian SST anomalies with West African rainfall has a strong seasonal cycle. In spring (May and June), anomalous subsidence develops over both the Maritime Continent and the equatorial Atlantic in response to the enhanced equatorial heating. Precipitation increases over continental West Africa in association with stronger zonal convergence of moisture. In addition, precipitation decreases over the Gulf of Guinea. During the monsoon peak (July and August), the SST anomalies move westward over the equatorial Pacific and the two regions where subsidence occurred earlier in the seasons merge over West Africa. The monsoon weakens and rainfall decreases over the Sahel, especially in August.Peer reviewe
    corecore